譜析(上海)生物科技有限公司提供——Levetiracetam (Keppra@) in Serum and Plasma 質(zhì)譜診斷方案
 
一、說明
The RECIPE analytical method for levetiracetam completes the RECIPE kit portfolio for the analysis of antiepileptic drugs (AED) with photometric detection. By the use of the same analytical column, the kits can easily be combined with the AED test kit with order no-. 14000 which allows the quantification of further 16 different drugs and clinically relevant metabolites.
 
二、產(chǎn)品優(yōu)勢
(1)One analytical column for levetiracetam and further 16 AEDs
 
三、測試數(shù)據(jù)
Linearity:                  0.5 - 1000
Recovery:                   97 - 105
LOD:                        0.15 mg/l
LLOQ:                       0.5 mg/l
Intraassay precision:      1.5  
Interassay precision:       1.9
 
四、高效液相色譜參數(shù)
Pump:                       isocratic pump, flow rate: 1.4 ml/min
Injection volume:           20 μI
Injection interval:         6 min
UV-Detector:                205 nm
HPLC-Thermostat:            30°C 
 
五、樣品制備
 
 
 